Documentation Index

Fetch the complete documentation index at: https://support.nectarcorp.com/llms.txt

Use this file to discover all available pages before exploring further.

Ports and Protocols Guide

Prev Next

During setup, the EPC Setup Wizard will offer to automatically create Windows firewall exceptions for the ports used by the agent and Controller. If this option is disabled, or if a third-party firewall is in use, ensure that the required local and remote ports are open to allow the agent to function properly.

Notes

The source of all traffic is the Endpoint Client.

Many of these processes are bidirectional and require both inbound and outbound access.

EPC requires that certain ICMP functions be enabled on the Windows host which are typically blocked by the Windows Firewall.  The EPC Setup Wizard automatically enables the minimal set of ICMP functionality required during Agent installation.

Controller Connection

To connect to the EPC controller, outbound traffic on TCP 443 will need to be enabled to the following IPs resolving to neccontroller.us.nectar.services:

52.204.230.133

34.231.219.110

50.17.99.212

Ports

Port Direction

Note that for Hubs, inbound traffic will need to be enabled for the following destinations:

  • UDP & TCP 5060/5061

  • UDP 29999

  • UDP 30000/50000

Regular EPC agents will not require inbound traffic for these destinations.

Destination

Protocol

Port Number(s)

Direction

Application

Controller

TCP

443

Outbound

HTTP Management

(Optional)

Controller

TCP

40006

Outbound

HTTP Management

(Optional) Internet

TCP/UDP

53

Outbound

DNS

(Optional) DHCP Server

UDP

67/68

Outbound

DHCP client

SIP Endpoint

UDP & TCP

5060/5061*

Outbound

SIP signaling

Peer Agent

UDP

29999*

Outbound

P2P Testing

Peer Endpoint

UDP

30000-50000

Outbound

Real-time media

(Optional) Variable

ICMP

N/A

Outbound

Inbound ICMP messages (required for some network tests)

* Default port number. A different port number can be assigned during setup/configuration of the Controller (see the Nectar EPC-Controller SSE Installation Guide or Nectar EPC-Controller MSE Installation Guide for details).